APC 208/240V Symmetra LX 16kVA Scalable to 16kVA N+1 Extended Run Tower

 
(Model # SYA16K16PXR)
Schneider Electric 208/240V Symmetra LX 16kVA Scalable to 16kVA N+1 Extended Run Tower
Schneider Electric

Note: Picture may not represent the actual product. We are continuously working on improving our website and reserve the right to change specifications, availability, and pricing without prior notice.

 
APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V. APC Symmetra, 12.8 kW / 16 kVA, Input 208V / Output 120V, 208V , Interface Port DB-9 RS-232, RJ-45 10/100 Base-T, Smart-Slot , Extended runtime model.
Extended Run Symmetra Features:
  • Shippable with modules installed: Enables pre-installation UPS staging and testing and faster installation
  • Removable input/output wiring tray: Allows quick and easy installation and maintenance of the UPS
  • Modular design: Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules
  • Configurable for N+1 internal redundancy: Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load
  • Redundant Intelligence Modules: Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions
  • Hot-swappable intelligence modules: Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement
  • Hot-swappable power modules: Ensures clean, uninterrupted power to protected equipment during Power Module replacement
  • Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
  • Power Modules connected in parallel: Enhances availability by allowing immediate, seamless recovery from isolated module failures
  • Battery modules connected in parallel: Delivers higher availability through redundant batteries
  • Automatic internal bypass: Supplies utility power to the connected loads in the event of a UPS overload condition or fault
  • Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power
  • Scalable power capacity: Reduces UPS over-sizing costs today by allowing quick upgrades later
  • Scalable runtime: Allows additional run time to be quickly added as needed
  • Plug-and-Play external batteries: Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
  • Field-replaceable power distribution panel: Ensures compatibility with equipment that has different plug types.
  • Programmable frequency: Ensures compatibility with different input frequencies
  • Manageable external batteries: Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime
  • Network manageable: Provides remote management of the UPS over the network
  • InfraStruXure Manager Compatible: Enables centralized management via the APC InfraStruXure Manager
  • LCD display: Alpha-Numeric Display which displays system parameters and alarms
  • Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging
  • SmartSlot: Customize UPS capabilities with management cards
  • Output Power Capacity: 12.8 kW / 16 kVA
  • Max Configurable Power: 12.8 kW / 16 kVA
  • Nominal Output Voltage: 120V,208V
  • Output Voltage Note: Configurable for 120/208 or 120/240 output voltage
  • Output Voltage Distortion: Less than 5% at full load
  • Output Frequency (sync to mains): 47 - 63 Hz
  • Other Output Voltages: 240
  • Crest Factor: up to 5 : 1
  • Topology: Double Conversion Online
  • Waveform Type: Sine wave
  • Output Connections: (1) Hard Wire 4-wire (2PH + N +G)
  • Bypass: Internal Bypass (Automatic and Manual),Optional External Bypass
  • Nominal Input Voltage: 208V
  • Input Frequency: 45 - 65 Hz (auto sensing)
  • Input Connections: Hard Wire 4-wire (2PH+N+G)
  • Input voltage range for main operations: 96 - 138 (Line to Neutral)V
  • Other Input Voltages: 240V
  • Input Total Harmonic Distortion: Less than 7% for full load
  • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : Leakproof
  • Included Battery Modules: 9
  • Available Battery Slots: 4
  • Typical recharge time: 7.50 hour(s)
  • Replacement Battery: SYBT5
  • Dimensions: 59.70" H x 19.00" W x 28.60" D
$19,651.11

Availability:
Usually ships in 5 days

Options
Dimensional Weight
Shipping Weight is calculated using actual physical product dimensions.
Multiple Quantities
Please call for freight costs on multiple quantities.
Shipping Costs
Additional shipping charges may apply. You will be contacted if necessary.

Qty:

Also Suggested

Open an Account

Similar Products
 
Advanced Search
Contact Us
TWAcomm Network
 
  
top
TWAatHome.com, Inc. is a leading provider of phone systems. We specialize in business phones and business phone systems for small to large companies; with phone systems for any application. All orders, small or large, are welcomed with no minimum order requirements.
GSA, Visa, MasterCard, and American Express Credit Cards Accepted
All logos displayed on this page are registered trademarks with their respective organizations.
Copyright © 1997 - 2024 TWAcomm.com, Inc. All rights reserved. - 3/28/2024 1:30:30 PM - v.8.0.16